<LOGO>
FM Transmitter Measurement Report
Created: 2025-08-08 08-44-26
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 52 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.4 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 71 kHz 16060 5,4234
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,3 dBr 4,66 dBr 6,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 71 kHz MIN: 12 kHz % above 76 kHz: 5,4234 Acquired: 2025/08/08 8.43.22 Total samples: 16060 Equivalent time: 0:13:23 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 6,1 dBr MIN: 2,3 dBr AVE: 4,66 dBr % above 12,2 dBr: 0,0 Last value: 4,6 dBr (2025/08/08 8.43.22) 08.30 08.32 08.34 08.36 08.38 08.40 08.42 0 2 4 6 Pm [dBr]